Product Description
Rated Temperature: 600C, 750C
Inner Conductor: bare solid or stranded copper,
Insulation: color coded PE insulation;
Drain Wire: bare solid or stranded copper;
Mylar Tape: transparent PET Mylar tape overlapped;
Shield: Aluminum/Polyester Foil overlapped, 100% coverage;
Braiding: bare copper wire braiding;
Ripcord : (Optional)
Jacket : PVC.
Standards: ISO/IEC 11801,ANSI/TIA/EIA-568A
*PE, LSF(Low Smoke & Fume) , LSZH(Low Smoke & Zero Halogen) and Lead Free/RoHS* version is available, too.
*Lead Free/RoHS comply with European Union’s(EU) Restriction of Hazardous Substances(Lead Free, Cadmium Free, Mercury Free & Chromium Free, PBB & PBDE Free)
Application
Used as work-station outlet to the FD/IDF
And other horizontal cabling, supporting TP-PMD Audio,
Integrated service digital network(ISDN),ATM155 Mbps,
100mbps TPDDI, Fast Ether-net etc.
CABLE CONSTRUCTION (S-FTP CAT6)
Part No. |
Specifications |
Conductor Dia.
(mm) |
Core Dia.
(mm) |
No. of Pairs |
Shielding |
Nom O.D. (mm) |
|
|
224301 |
S-FTP |
0.57 |
1.00 |
4 |
Al Foil + Cu Braiding |
6.6 |
|
ELECTRICAL CHARACTERISTICS(S-FTP CAT6 solid conductor)
Frequency
(MHz) |
Impedance
(Ohm) |
Return Loss
(dB) |
Attenuation (dB/100m) |
Next Worst Pair (dB) |
Next Power
Sum (dB) |
ELFEXT Worst
Pair (dB) |
ELFEXT Power
Sum(dB) |
Nominal Velocity
Propagation |
|
|
1.0 |
100 15
|
20.0 |
2.0 |
74.3 |
72.3 |
67.8 |
64.8 |
0.65 |
|
4.0 |
23.0 |
3.8 |
65.3 |
63.3 |
55.8 |
52.8 |
|
8.0 |
24.5 |
5.3 |
60.8 |
58.8 |
49.7 |
46.7 |
|
10.0 |
25.0 |
6.0 |
59.3 |
57.3 |
47.8 |
44.8 |
|
16.0 |
25.0 |
7.6 |
56.2 |
54.2 |
43.7 |
40.7 |
|
20.0 |
25.0 |
8.5 |
54.8 |
52.8 |
41.8 |
38.8 |
|
25.0 |
24.3 |
9.5 |
53.3 |
51.3 |
39.8 |
36.8 |
|
31.25 |
23.6 |
10.7 |
51.9 |
49.9 |
37.9 |
34.9 |
|
62.5 |
21.5 |
15.4 |
47.4 |
45.4 |
31.9 |
28.9 |
|
100.0 |
20.1 |
19.8 |
44.3 |
42.3 |
27.8 |
24.8 |
|
200.0 |
100 22 |
18.0 |
29.0 |
39.8 |
37.8 |
21.8 |
18.8 |
|
250.0 |
17.3 |
32.8 |
38.3 |
36.3 |
19.8 |
16.8 |
|
CABLE CONSTRUCTION (PATCH CABLE CAT6 - AWG 26)
Part No. |
Specifications |
Conductor Dia.
(mm) |
Core Dia.
(mm) |
No. of Pairs |
Shielding |
Nom O.D. (mm) |
|
|
224302 |
Patch S-FTP AWG26 |
7/0.16 |
0.86 |
4 |
Al Foil + Cu Braiding |
6.1 |
|
ELECTRICAL CHARACTERISTICS(PATCH CABLE S-FTP CAT6-AWG26)
Frequency
(MHz) |
Impedance
(Ohm) |
Return Loss
(dB) |
Attenuation (db/100m) |
Next Worst Pair (dB) |
Next Power
Sum (dB) |
ELFEXT Worst
Pair (dB) |
ELFEXT Power
Sum (dB) |
Nominal Velocity
Propagation |
1.0 |
100 15 |
20.0 |
3.1 |
74.3 |
72.3 |
67.8 |
64.8 |
0.65 |
4.0 |
23.0 |
6.1 |
65.3 |
63.3 |
55.8 |
52.8 |
8.0 |
24.5 |
8.6 |
60.8 |
58.8 |
49.7 |
46.7 |
10.0 |
25.0 |
9.7 |
59.3 |
57.3 |
47.8 |
44.8 |
16.0 |
25.0 |
12.4 |
56.2 |
54.2 |
43.7 |
40.7 |
20.0 |
25.0 |
13.9 |
54.8 |
52.8 |
41.8 |
38.8 |
25.0 |
24.2 |
15.6 |
53.3 |
51.3 |
39.8 |
36.8 |
31.25 |
23.3 |
17.6 |
51.9 |
49.9 |
37.9 |
34.9 |
62.5 |
20.7 |
25.5 |
47.4 |
45.4 |
31.9 |
28.9 |
100.0 |
19.0 |
33.0 |
44.3 |
42.3 |
27.8 |
24.8 |
200.0 |
100 22 |
16.4 |
48.6 |
39.8 |
37.8 |
21.8 |
18.8 |
250.0 |
15.5 |
55.3 |
38.3 |
36.3 |
19.8 |
16.8 | |