Part No. |
Type |
Conductor |
Insulation |
Braid Shield |
Jacket |
Imp |
Cap |
Atten |
|
First
Braid
coverage |
Second
Braid
coverage |
MTRL |
|
No./mm |
MTRL |
Dia. |
MTRL |
Nom. Dia. |
MTRL |
Ohm |
pF/m |
100MHz |
|
mm |
mm |
RG MIL-C-17F
|
116001 |
RG-6/U |
1/1.024 |
CCS |
4.57 |
LDPEF |
98% |
98% |
TC |
7.40+/-0.20 |
PVC |
75 |
56.8 |
69dB/Km |
|
116002 |
RG-7/U |
1/0.914 |
BC |
6.53 |
LDPE |
95% |
---- |
BC |
9.40+/-0.20 |
PVC |
94.5 |
41.0 |
68dB/Km |
|
116003 |
RG-8/U |
7/0.724 |
BC |
7.24 |
LDPE |
95% |
---- |
BC |
10.30+/-0.20 |
PVC |
52 |
96.8 |
69dB/Km |
|
116004 |
RG-8A/U |
7/0.724 |
BC |
7.24 |
LDPE |
95% |
---- |
BC |
10.30+/-0.20 |
NCPVC |
52 |
96.8 |
69dB/Km |
|
116005 |
RG-11/U |
7/0.404 |
TC |
7.24 |
LDPE |
95% |
---- |
BC |
10.30+/-0.20 |
PVC |
75 |
67.3 |
76dB/Km |
|
116006 |
RG-11A/U |
7/0.404 |
TC |
7.24 |
LDPE |
95% |
---- |
BC |
10.30+/-0.20 |
NCPVC |
75 |
67.3 |
76dB/Km |
|
116007 |
RG-13/U |
7/0.404 |
TC |
7.11 |
LDPE |
95% |
95% |
BC |
10.70+/-0.20 |
PVC |
74 |
67.3 |
76dB/Km |
|
116008 |
RG-13A/U |
7/0.404 |
TC |
7.11 |
LDPE |
95% |
95% |
BC |
10.70+/-0.20 |
NCPVC |
74 |
67.3 |
76dB/Km |
|
116009 |
RG-14/U |
1/2.590 |
BC |
9.4 |
LDPE |
98% |
98% |
BC |
13.80+/-0.20 |
PVC |
52 |
96.8 |
46dB/Km |
|
116010 |
RG-14A/U |
1/2.590 |
CCS |
9.4 |
LDPE |
98% |
98% |
TC |
13.80+/-0.20 |
NCPVC |
52 |
96.8 |
48dB/Km |
|
116011 |
RG-15/U |
1/1.450 |
BC |
9.4 |
LDPE |
98% |
98% |
BC |
13.80+/-0.20 |
PVC |
76 |
65.6 |
49dB/Km |
|
116012 |
RG-17/U |
1/4.780 |
BC |
17.3 |
LDPE |
95% |
---- |
BC |
22.10+/-0.35 |
PVC |
52 |
96.8 |
28dB/Km |
|
116013 |
RG-17A/U |
1/4.780 |
BC |
17.3 |
LDPE |
95% |
---- |
BC |
22.10+/-0.35 |
NCPVC |
52 |
96.8 |
28dB/Km |
|
116014 |
RG-19/U |
1/6.350 |
BC |
23.1 |
LDPE |
91% |
---- |
BC |
28.50+/-0.40 |
PVC |
52 |
96.8 |
22dB/Km |
|
116015 |
RG-19A/U |
1/6.350 |
BC |
23.1 |
LDPE |
91% |
---- |
BC |
28.50+/-0.40 |
NCPVC |
52 |
96.8 |
22dB/Km |
|
116016 |
RG-22/U |
7/0.386x2C |
BC |
7.24 |
LDPE |
95% |
---- |
BC |
10.30+/-0.20 |
PVC |
96 |
52.5 |
118dB/Km |
|
116017 |
RG-22A/U |
7/0.386x2C |
BC |
7.24 |
LDPE |
95% |
95% |
BC |
10.70+/-0.20 |
PVC |
96 |
52.5 |
118dB/Km |
|
116018 |
RG-22B/U |
7/0.386x2C |
BC |
7.24 |
LDPE |
95% |
95% |
BC |
10.70+/-0.20 |
NCPVC |
95 |
52.5 |
118dB/Km |
|
116019 |
RG-29/U |
1/0.813 |
BC |
2.95 |
LDPE |
95% |
---- |
BC |
4.70+/-0.15 |
PE |
53.6 |
93.5 |
138dB/Km |
|
116020 |
RG-34/U |
7/0.724 |
BC |
11.6 |
LDPE |
91% |
---- |
BC |
15.90+/-0.25 |
PVC |
71 |
70.5 |
46dB/Km |
|
116021 |
RG-34B/U |
7/0.632 |
BC |
11.7 |
LDPE |
91% |
---- |
BC |
16.00+/-0.25 |
NCPVC |
75 |
67.0 |
48dB/Km |
|
116022 |
RG-54A/U |
7/0.366 |
BC |
4.52 |
LDPE |
98% |
---- |
BC |
6.10+/-0.15 |
PE |
58 |
86.8 |
187dB/Km |
|
116023 |
RG-55/U |
1/0.813 |
BC |
2.9 |
LDPE |
95% |
95% |
BC |
5.00+/-0.15 |
PE |
53.5 |
93.6 |
138dB/Km |
|
116024 |
RG-58/U |
1/0.813 |
BC |
2.95 |
LDPE |
95% |
---- |
TC |
4.95+/-0.15 |
PVC |
53.5 |
93.5 |
138dB/Km |
|
116025 |
RG-58A/U |
19/0.180 |
TC |
2.95 |
LDPE |
95% |
---- |
TC |
4.95+/-0.15 |
PVC |
50 |
93.5 |
174dB/Km |
|
116026 |
RG-58C/U |
19/0.180 |
TC |
2.95 |
LDPE |
95% |
---- |
TC |
4.95+/-0.15 |
NCPVC |
50 |
93.5 |
174dB/Km |
|
116027 |
RG-59/U |
1/0.643 |
CCS |
3.71 |
LDPE |
95% |
---- |
BC |
6.15+/-0.15 |
PVC |
73 |
68.9 |
125dB/Km |
|
116028 |
RG-59A/U |
1/0.643 |
CCS |
3.71 |
LDPE |
95% |
---- |
TC |
6.15+/-0.15 |
NCPVC |
73 |
68.9 |
125dB/Km |
|
116029 |
RG-59B/U |
1/0.584 |
CCS |
3.71 |
LDPE |
95% |
---- |
BC |
6.15+/-0.15 |
NCPVC |
73 |
68.9 |
112dB/Km |
|
116030 |
RG-62/U |
1/0.643 |
CCS |
3.71 |
LDPE |
95% |
---- |
BC |
6.15+/-0.15 |
PVC |
93 |
44.3 |
102dB/Km |
|
116031 |
RG-62A/U |
1/0.643 |
CCS |
3.71 |
LDPE |
95% |
---- |
BC |
6.15+/-0.15 |
NCPVC |
93 |
44.3 |
102dB/Km |
|
116032 |
RG-63/U |
1/0.643 |
CCS |
7.24 |
LDPE |
95% |
---- |
BC |
10.30+/-0.20 |
PVC |
125 |
32.8 |
66dB/Km |
|
116033 |
RG-63B/U |
1/0.643 |
CCS |
7.24 |
LDPE |
95% |
---- |
BC |
10.30+/-0.20 |
NCPVC |
125 |
32.8 |
66dB/Km |
|
116034 |
RG-71/U |
1/0.643 |
CCS |
3.71 |
LDPE |
95% |
95% |
BC |
6.40+/-0.15 |
PE |
93 |
44.3 |
102dB/Km |
|
116035 |
RG-89/U |
1/0.643 |
CCS |
7.24 |
LDPE |
95% |
---- |
BC |
16.00+/-0.25 |
PVC |
125 |
32.8 |
66dB/Km |
|
116036 |
RG-108/U |
7/0.320x2C |
TC |
1.84 |
LDPE |
98% |
---- |
BC |
6.20+/-0.15 |
NCPVC |
78 |
74.3 |
------- |
|
116037 |
RG-108A/U |
7/0.320X2C |
TC |
2.01 |
LDPE |
98% |
---- |
BC |
5.97+/-0.15 |
NCPVC |
78 |
74.3 |
------- |
|
116038 |
RG-122/U |
27/0.127 |
TC |
2.44 |
LDPE |
95% |
---- |
BC |
4.06+/-0.15 |
NCPVC |
50 |
105.0 |
195dB/Km |
|
116039 |
RG-130/U |
7/0.724x2C |
BC |
12 |
LDPE |
91% |
---- |
BC |
15.90+/-0.25 |
PVC |
95 |
56.0 |
99dB/Km |
|
116040 |
RG-133A/U |
1/0.645 |
BC |
7.2 |
LDPE |
95% |
---- |
BC |
10.30+/-0.20 |
NCPVC |
95 |
53.0 |
76dB/Km |
|
116041 |
RG-164/U |
1/2.650 |
BC |
17.3 |
LDPE |
91% |
---- |
BC |
22.10+/-0.35 |
NCPVC |
75 |
67.0 |
30dB/Km |
|
116042 |
RG-174/U |
7/0.160 |
CCS |
1.52 |
LDPE |
98% |
---- |
TC |
2.54+/-0.15 |
NCPVC |
50 |
110.0 |
259dB/Km |
|
116043 |
RG-213/U |
7/0.752 |
BC |
7.24 |
LDPE |
95% |
---- |
BC |
10.30+/-0.20 |
NCPVC |
50 |
100.0 |
69dB/Km |
|
116044 |
RG-216/U |
7/0.404 |
TC |
7.24 |
LDPE |
95% |
95% |
BC |
10.80+/-0.20 |
NCPVC |
75 |
67.0 |
88dB/Km |
|
Note
BC-Bare copper wire
TC-Tinned copper wire
CCS-Copper coated steel wire
PVC-Polyvinylchloride
NCPVC-Non contaminating polyvinylchloride
PE-Polyethylene
LDPE-Low density polyethylene
LDPEF-Low density foam polyethylene
PE, LSF(Low Smoke & Fume) , LSZH(Low Smoke & Zero Halogen) , RBS* and Duct version is available, too.
*RBS is co-extruded polyethylene and polypropylene Dual sheathed, used in outdoor, underground duct or direct burial applications.
RoHS Complaints(2002/95/EC)