Product Description
Rated Voltage:300V, Rated Temperature:200°C
Conductor: tinned, stranded or solid copper, min.26AWG
Insulation: silicone rubber;.
Braid: color-coded fiber glass
Passes UL VW-1 vertical flame test.
Resistant to heat and cold.
Application
For internal wiring of electrical equipment in high temperature condition.
UL 3122 300V 200°C
Part No. |
Conductor
type |
Conductor |
Jacket |
Max
Resistance
At 20°C |
Max Conductor
Resistance
At 20°C |
Dielectric
Strength
AC 1min |
Specification
Sheet
|
Spec |
No./mm |
Nom. Dia. |
Nom. Thick. |
Nom. Dia |
AWG |
mm |
mm |
mm |
mm |
Ω /KM |
MΩ.KM |
V |
211001 |
Stranded
Conductor |
26 |
7/0.16 |
0.48 |
0.60 |
1.68 |
139.73 |
139.73 |
1500 |
|
211002 |
24 |
11/0.16 |
0.61 |
0.60 |
1.81 |
93.3 |
93.3 |
|
211003 |
22 |
17/0.16 |
0.76 |
0.65 |
2.06 |
55.0 |
55.0 |
|
211004 |
20 |
26/0.16 |
0.94 |
0.65 |
2.24 |
34.6 |
34.6 |
|
211005 |
18 |
41/0.16 |
1.18 |
0.65 |
2.48 |
21.8 |
21.8 |
|
211006 |
16 |
26/0.254 |
1.49 |
0.65 |
2.79 |
13.7 |
13.7 |
|
211007 |
14 |
41/0.254 |
1.88 |
0.65 |
3.18 |
8.62 |
8.62 |
|
211008 |
12 |
65/0.254 |
2.37 |
0.90 |
4.17 |
5.43 |
5.43 |
|
211009 |
10 |
105/0.254 |
3.40 |
0.90 |
5.20 |
3.41 |