Home » Products »Cable and Wire » Multipair Cable » Foil Shield » Foam PP/PVC 300V 80℃
 
PVC/PVC 300V 80℃PVC/PVC 150V 80℃PVC/PVC 300V 105℃PE/PVC 300V 80℃Foam PP/PVC 300V 80℃PE/PVC 600V 80℃
Foam PP/PVC 300V 80℃

Product Description

Rated Voltage  300V ,  Rated Temperature  80°C

Inner Conductor:  Tinned Copper

Insulation: Color-Coded Foam PP, Color Code: Chart A

Shield: Overall Aluminum/Polyester Foil overlapped, Foil Facing Outward.

Drain Wire:

24AWG(7/0.20mm) Stranded Tinned Copper For Multipair cable of conductor 24AWG(7/0.20mm).

22AWG(7/0.254mm) Stranded Tinned Copper For Multipair cable of conductor 22AWG(7/0.254mm).

Jacket: PVC

 

PE, LSF(Low Smoke & Fume) , LSZH(Low Smoke & Zero Halogen) and Lead Free/RoHS* version is available, too.

 

*Lead Free/RoHS comply with European Union’s(EU) Restriction of Hazardous Substances & European Standard

EN 71 Part3: 1994 + A1. 2000

 

Application

Computer Interconncets

EIA RS-232/422 Applications

CAD/CAM System

External Interconnection of Computer or Electronic Point-of-Sale Equipment in Areas Where Medium to High

Levels of Noise Interference are Anticipated

Extended Distance

 

Specifications according to UL2919  300V  80°C

Part No.

Belden

Part No.

Alpha

Part No.

Carol

Part No.

Conductor

(Stranded)

No.of

Pairs

Insulation

Thckness

Jacket

Specification

Sheet

Nom.

Thick

Nom.

Dia.

Imm

mm

mm

142501

1419A

6202C

 

24AWG(7/0.20mm)

2

0.41

0.89

6.30

 

142502

1420A

6203C

 

24AWG(7/0.20mm)

3

0.41

0.89

6.60

 

142503

1421A

6204C

 

24AWG(7/0.20mm)

41/2

0.41

0.89

7.30

   

142504

1422A

6205C

 

24AWG(7/0.20mm)

5

0.41

0.89

7.80

   

142505

1423A

6206C

 

24AWG(7/0.20mm)

6

0.41

0.89

8.60

   

142506

 

6207C

 

24AWG(7/0.20mm)

7

0.41

0.89

8.80

   

142507

 

6028C

 

24AWG(7/0.20mm)

8

0.41

0.89

9.10

   

142508

 

6209C

 

24AWG(7/0.20mm)

9

0.41

0.89

9.90

   

142509

 

6210C

 

24AWG(7/0.20mm)

10

0.41

0.89

10.60

 

142510

1424A

6210/12C

 

24AWG(7/0.20mm)

121/2

0.41

0.89

10.90

   

142511

1425A

6210/15C

 

24AWG(7/0.20mm)

15

0.41

0.89

12.20

   

142512

 

6210/18C

 

24AWG(7/0.20mm)

181/2

0.41

1.27

13.50

 

142513

 

6210/25C

 

24AWG(7/0.20mm)

25

0.41

1.27

14.50

   

 

Part No.

Belden

Part No.

Alpha

Part No.

Carol

Part No.

Conductor

(Stranded)

No. of

Pairs

Insulation

Thickness

Jacket

Specification

Sheet

Nom.

Thick

Nom.

Dia.

mm

mm

mm

142514

 

6212C

 

22AWG(7/0.254mm)

2

0.51

0.89

7.40

 

142515

 

6213C

 

22AWG(7/0.254mm)

3

0.51

0.89

7.90

   

142516

 

6216C

 

22AWG(7/0.254mm)

6

0.51

0.89

9.90

   

142517

 

6217C

 

22AWG(7/0.254mm)

7

0.51

0.89

10.20

   

142518

 

6218C

 

22AWG(7/0.254mm)

8

0.51

0.89

10.70

   

142519

 

6220C

 

22AWG(7/0.254mm)

10

0.51

0.89

12.20

   

142520

 

6220/12C

 

22AWG(7/0.254mm)

121/2

0.51

1.27

13.50

   

142521

 

6220/15C

 

22AWG(7/0.254mm)

15

0.51

1.27

14.50

   

142522

 

6220/18C

 

22AWG(7/0.254mm)

181/2

0.51

1.27

15.20

   

142523

 

6220/25C

 

22AWG(7/0.254mm)

25

0.51

1.27

17.80

   

 

Note

C to C is Conductor D.R. to Conductor D.R.

CtoC + Sh is Conductor D.R. to Conductor D.R. & Shield.

ADDRESS: 603-608, Huahong 5TH Avenue, No. 719 Zhongxing Road, Ningbo,China 315040
TEL: 0086 574 8728 8314, 8725 5118       FAX: 0086 574 8734 3958
E-mail:mainning@mainning.com.cn