Product Description
Rated Voltage 300V , Rated Temperature 80°C
Inner Conductor: Tinned Copper
Insulation: Color-Coded Foam PP, Color Code: Chart A
Shield: Overall Aluminum/Polyester Foil overlapped, Foil Facing Outward.
Drain Wire:
24AWG(7/0.20mm) Stranded Tinned Copper For Multipair cable of conductor 24AWG(7/0.20mm).
22AWG(7/0.254mm) Stranded Tinned Copper For Multipair cable of conductor 22AWG(7/0.254mm).
Jacket: PVC
PE, LSF(Low Smoke & Fume) , LSZH(Low Smoke & Zero Halogen) and Lead Free/RoHS* version is available, too.
*Lead Free/RoHS comply with European Union’s(EU) Restriction of Hazardous Substances & European Standard
EN 71 Part3: 1994 + A1. 2000
Application
Computer Interconncets
EIA RS-232/422 Applications
CAD/CAM System
External Interconnection of Computer or Electronic Point-of-Sale Equipment in Areas Where Medium to High
Levels of Noise Interference are Anticipated
Extended Distance
Specifications according to UL2919 300V 80°C
Part No. |
Belden
Part No. |
Alpha
Part No. |
Carol
Part No. |
Conductor
(Stranded) |
No.of
Pairs |
Insulation
Thckness |
Jacket |
Specification
Sheet |
Nom.
Thick |
Nom.
Dia. |
Imm |
mm |
mm |
142501 |
1419A |
6202C |
|
24AWG(7/0.20mm) |
2 |
0.41 |
0.89 |
6.30 |
|
142502 |
1420A |
6203C |
|
24AWG(7/0.20mm) |
3 |
0.41 |
0.89 |
6.60 |
|
142503 |
1421A |
6204C |
|
24AWG(7/0.20mm) |
41/2 |
0.41 |
0.89 |
7.30 |
|
142504 |
1422A |
6205C |
|
24AWG(7/0.20mm) |
5 |
0.41 |
0.89 |
7.80 |
|
142505 |
1423A |
6206C |
|
24AWG(7/0.20mm) |
6 |
0.41 |
0.89 |
8.60 |
|
142506 |
|
6207C |
|
24AWG(7/0.20mm) |
7 |
0.41 |
0.89 |
8.80 |
|
142507 |
|
6028C |
|
24AWG(7/0.20mm) |
8 |
0.41 |
0.89 |
9.10 |
|
142508 |
|
6209C |
|
24AWG(7/0.20mm) |
9 |
0.41 |
0.89 |
9.90 |
|
142509 |
|
6210C |
|
24AWG(7/0.20mm) |
10 |
0.41 |
0.89 |
10.60 |
|
142510 |
1424A |
6210/12C |
|
24AWG(7/0.20mm) |
121/2 |
0.41 |
0.89 |
10.90 |
|
142511 |
1425A |
6210/15C |
|
24AWG(7/0.20mm) |
15 |
0.41 |
0.89 |
12.20 |
|
142512 |
|
6210/18C |
|
24AWG(7/0.20mm) |
181/2 |
0.41 |
1.27 |
13.50 |
|
142513 |
|
6210/25C |
|
24AWG(7/0.20mm) |
25 |
0.41 |
1.27 |
14.50 |
|
Part No. |
Belden
Part No. |
Alpha
Part No. |
Carol
Part No. |
Conductor
(Stranded) |
No. of
Pairs |
Insulation
Thickness |
Jacket |
Specification
Sheet |
Nom.
Thick |
Nom.
Dia. |
mm |
mm |
mm |
142514 |
|
6212C |
|
22AWG(7/0.254mm) |
2 |
0.51 |
0.89 |
7.40 |
|
142515 |
|
6213C |
|
22AWG(7/0.254mm) |
3 |
0.51 |
0.89 |
7.90 |
|
142516 |
|
6216C |
|
22AWG(7/0.254mm) |
6 |
0.51 |
0.89 |
9.90 |
|
142517 |
|
6217C |
|
22AWG(7/0.254mm) |
7 |
0.51 |
0.89 |
10.20 |
|
142518 |
|
6218C |
|
22AWG(7/0.254mm) |
8 |
0.51 |
0.89 |
10.70 |
|
142519 |
|
6220C |
|
22AWG(7/0.254mm) |
10 |
0.51 |
0.89 |
12.20 |
|
142520 |
|
6220/12C |
|
22AWG(7/0.254mm) |
121/2 |
0.51 |
1.27 |
13.50 |
|
142521 |
|
6220/15C |
|
22AWG(7/0.254mm) |
15 |
0.51 |
1.27 |
14.50 |
|
142522 |
|
6220/18C |
|
22AWG(7/0.254mm) |
181/2 |
0.51 |
1.27 |
15.20 |
|
142523 |
|
6220/25C |
|
22AWG(7/0.254mm) |
25 |
0.51 |
1.27 |
17.80 |
|
Note
C to C is Conductor D.R. to Conductor D.R.
CtoC + Sh is Conductor D.R. to Conductor D.R. & Shield. |